RK5, RK7 - Radiation covers
- UV resistant plastic lamellas with low thermal conductivity and high reflectivity
- The basic version of the RK contains 5 or 7 slats
- Minimum airflow resistance
- Easy and fast clamping of the sensor in a plastic collet
- Included stainless steel holder for attaching the agency to the mast
- Extensive range of suitable sensors and transducers
Use and basic description
Radiation covers RK5 and RK7 are designed to protect temperature and relative humidity sensors from the effects of radiant heat radiation and rain. The use of a radiation shield minimizes the temperature measurement error that would otherwise occur on a sunlit temperature sensor.
The delivery of the radiation cover also includes a stainless steel universal holder, which can be attached both to a vertical surface and to a pole with a diameter of 1.5 "to 2.5". A stainless steel clamp of suitable size can be ordered together with the delivery of the radiation cover.
The compact design and large space inside the housing allow these covers to be used for many other applications.
Mechanical design of RK
Radiation shields are made of special plastic with high reflectivity for incident radiation, have low thermal conductivity and are long-term resistant to both rain and wind and UV radiation.
The shape of the radiation shield and their arrangement prevents the impact of direct thermal radiation on the sensor and minimizes the effect of reflected radiation. The passage of air to the sensor, on the other hand, is almost unlimited.
Unlike the RK5 cover, the RK7 radiation cover contains a double solid lamella on the top of the cover for better protection of the sensor against radiant radiation. This cover also has a higher internal space for the sensor given by another lamella located in the body of the cover.
Sensor mounting bracket
The temperature, relative humidity or other combined sensor is attached to the radiation cover RK5 (RK7) by means of a screw lamella clamp, which is attached in the middle of the stainless steel sensor holder and is freely accessible to the user from the bottom of the holder. This way of mounting the sensor allows its easy and quick replacement in case of damage.
The maximum diameter of the inserted sensor is 20 mm in the standard version of the holder. Brackets with a larger hole for more robust sensors can be supplied on request. It is also possible to increase the number of lamellae, if required by the length of the considered sensor.
Types of sensors adapted for installation in radiation shields RK5, RK7:
Pt100-XM: air temperature (±0.3 °C)
encapsulated Pt100-A sensor without electronics, four-wire connection to the measuring unit with PUR cable
TEP01: air temperature (±0.3 °C)
Precision sensor with Pt100-A sensor, RS485 output (FINET and Modbus RTU), connection via M12/4 connector or PUR cable
RVT80: relative humidity (±1.8%) and air temperature (±1 °C)
Sensor with SHT85 sensor, RS485 output (FINET and Modbus RTU), connection via M12 4 connector
RVT81: relative humidity (±1.8%) and air temperature (±0.3 °C)
Relative humidity sensor with SHT85 sensor, temperature measurement with Pt100-A sensor, RS485 output (FINET and Modbus RTU), connection via M12 / 4 connector
RVT12: relative humidity (±0.8%) and air temperature (±0.1 °C)
High-precision relative humidity and air temperature sensor with combined ROTRONIC sensor, output 2x 0 to 1 V DC, connection via M12 / 4 connector
RVT13: relative humidity (±0.8%) and air temperature (±0.1 °C)
High-precision relative humidity and air temperature sensor with combined ROTRONIC sensor, RS485 output (FINET and Modus RTU), connection via M12 / 4 connector
ATM01: atmospheric air pressure (±1 mbar) Atmospheric air pressure sensor, RS485 output (FINET and Modus RTU), connection via M12 / 4 connector
ATM11: atmospheric pressure (±1 mbar) and air temperature (±0.3 °C)
Atmospheric pressure and air temperature sensor, RS485 output (FINET and Modus RTU), connection via M12 / 4 connector
Recommendations for the location of the agency
Radiation covers RK5 and RK7 are designed for their permanent placement in the outdoor environment. In order for the cover to perform its function well, follow the following recommendations when installing it:
- Install the cover in places with good airflow. This will increase the accuracy of the measured air temperature
- Avoid placing the cover over large dark areas and massive structures (solar panels, asphalt surfaces, sheet metal roofs, etc.)
- Keep a sufficient distance from water jets, fountains and other sources of splashing water
- Do not place radiation shields near air conditioners and vents
- Reliable and accurate measurements will be difficult to perform near sources of electromagnetic interference (electrical power lines, power motors, ...)
Service and maintenance
Radiation covers RK5 and RK7 do not require any other regular maintenance except for possible dust removal from individual lamellas. The best way to remove long-term dirt is with a cloth soaked in soapy water.
Basic technical parameters
Parameter | Value |
External dimensions | diameter 150 mm, height 130 mm (RK5) and 170 mm (RK7) |
Interior space | diameter 32 mm, height 110 mm (RK5) and 130 mm (RK7) |
Number of slats | 5 (RK5) or 7 (RK7) |
Slat material | UV resistant, highly reflective thermoplastic, thickness 3mm |
Konstrukce | stainless steel posts |
Sensor mounting | plastic collet with an inner diameter of 17 mm |
Weight including holder | RK5: 550 g, RK7: 660 g |
Diameter of the column | 30 to 63 mm |
Optional accessories | nerezový montážní třmen 1", 1 1/2" and 2" |
Operating temperature | -50 °C to +80 °C |
Main menu
- Solutions
- Tap water treatment
- Dispatching accessible via the Internet
- Remote water meter reading
- Monitoring of water leak
- Measurement of qualitative water parameters
- Measurement in Water Supply Network
- Pressures and flows regulation
- Controlling of water pumps and water reservoirs
- Controlling technology of waste purification plants
- Flow processing into charts
- Waste water treatment
- Monitoring of running and technology of WWTP
- Control technology of WWTP
- Measurement of waste water flow
- Dissolved oxygen measurement and aeration blowers control
- Measurement of chemical parameters of water
- Local control of pumping stations
- Remote control of pumping stations
- Root zone waste water treatment plants
- Dispatching accessible via the Internet
- Processing of measured flow data
- Water level monitoring
- Flood warning system
- Environmental monitoring
- Water level and flow monitoring in small water-courses
- Temperature measurement in bore holes and water basins
- Monitoring of soil humidity and temperatures
- Measurement of rain-fall quantity and intensity
- Level measurement in boreholes and remote data collecting
- Measurement of water temperature and conductivity in boreholes
- Measurement of well yield – pumping tests
- Water-level regulation in boreholes
- Capacity and intensity of drainage water
- Thermal balance in ecological constructions
- Meteorological stations
- Relative humidity and air temperature, rainfall, global radiating, atmospheric pressure, speed and direction of wind
- Satellite transfer while the GSM signal is unavailable
- Meteorological stations for agriculture and research institutes
- Extension of meteorological stations about special sensors
- Different type of tower constructions
- Data transfers into the Internet
- Special kinds of graphs for visualization
- Irrigation control systems
- Data collecting and processing
- Data hosting on the server
- Software MOST
- Parameterization of stations via the Internet
- Transferring of measured data into a current dispatcher programme
- Visualization and processing of data
- Data exports from the server into the PC
- Overview reports working-out and printing
- An automatic emails sending
- Types of SIM cards
- Operating costs of the telemetric station
- Industrial applications
- Tap water treatment
- Products
- Monitoring and control units for water supply
- Small telemetric stations and data loggers
- Smart Metering - remote meter readings
- Water level meters
- Hydrostatic level meters
- Radar level meters
- Ultrasonic level meters
- Level gauges for wells, boreholes and reservoirs
- Level float switches
- Equipment for pumping tests of boreholes and wells
- Local Warning Systems
- Flow meters for open channels
- Water quality sensors
- Meteorological stations and measuring sensors
- Accessories for control units and data loggers
- Boxes and cabinets for telemetry and control units
- Gel accumulators, batteries and backup sources
- AC power supplies and battery chargers
- Photovoltaic solar panels
- Antennas and extension cables
- Sensor cables, connectors and connecting expanders
- Communication signal converters and communication cables
- Mechanical mounting elements
- Industrial and residential water meters
- Server software and services
- References
- Support & Download
- About us
- Monitoring
- Datahosting
Documentation
Download
Application
no related solutions